Fast Electric 50 amp controller

click for more details
    click photo for PDF 149 kB
  • Remote arming/disarming ability
  • Variable throttle span and zero point
  • Switchable Battery Elimination Circuit
  • 0 to 26 Volt range (7-26 with B.E.C.)
  • Low loss 0.0015 ohm FET output
  • overload protected
  • glitch-free with a poor radio signal
  • AUDIBLE Arm Status and thermal trip
  • VISIBLE Throttle/Radio/Thermal Cutout
  • smooth high frequency operation
  • Dimension 53 x 30 x 13 mm
  • operates glitch-free with a poor radio signal
SETUP

Throttle lever position

To align the controller to your throttle lever.....
position the throttle below.
Then give the SETUP button
zero throttle point
one press
maximum throttle point
two presses

Disarm mode setup

Hold the setup button...
After two seconds the four lights flash sequentially
 Release on the flashing colour below.
For disarming on...
RED
ALWAYS ARMED
(default reset setting)
YELLOW
Battery disconnection
GREEN
Battery disconnection 
2.5 seconds of radio failure
INTENSE RED
Battery disconnection
1.4 seconds of radio failure

To reset to default : press SETUP with transmitter off

To arm the throttle : reverse stick for 2 seconds

INDICATORS

                STATUS                 VISIBLE INDICATION     AUDIBLE INDICATION
RADIO FAILURE 
RED indicator light 
 
UNARMED 
INTENSE RED light
continuous chirps
TEMPERATURE CUTOUT
lights flashing alternately
double chirps
THROTTLE
YELLOW brightness = power
 
MAXIMUM THROTTLE
YELLOW flashing